| Quality
Engineering Test Report |
|
SERIES
: AP 12-030
300W DC-AC POWER INVERTER
|
| SAMPLE: |
AP12-030
CE |
I/P:12VDC,
O/P:230VAC 50Hz |
|
|
|
NO
|
TEST
ITEM
|
TEST
CONDITION / SPECIFICATION
|
TYPICAL
RESULT
|
VERDICT |
|
1
|
DC
INPUT VOLTAGE RANGE
|
|
I/P
: TESTING
|
SPEC
:
|
10~15VDC
|
|
O/P
: 300W
|
|
|
|
9.9~15VDC
|
|
|
2
|
BATTERY
LOW ALARM
|
|
I/P
: TESTING
|
SPEC
:
|
10.5±0.5VDC
|
|
O/P
: 300W
|
|
|
|
10.15VDC
|
|
|
3
|
BATTERY
LOW SHUTDOWN
|
|
I/P
: TESTING
|
SPEC
:
|
10±0.5VDC
|
|
O/P
: 300W
|
|
|
|
10.9VDC
|
|
|
4
|
LINE
REGULATION
|
|
I/P
: 10~15VDC
|
SPEC
:
|
±10%
|
|
O/P
: 300W
|
|
|
|
205~235VAC
|
|
|
5
|
LOAD
REGULATION
|
|
I/P
: 12VDC
|
SPEC
:
|
±10%
|
|
O/P
: 0~300W
|
|
208~224VAC
|
|
|
6
|
OUTPUT
FREQUENCY
|
|
I/P
: 12VDC
|
SPEC
:
|
50Hz
|
|
O/P
: 300W
|
|
|
|
B:50.0Hz
|
|
|
7
|
OUTPUT
WAVEFORM
|
|
I/P
: 12VDC
|
SPEC
:
|
MODIFIED
|
|
O/P
: 300W
|
|
SINEWAVE
|
|
SQUARE
WAVE
|
|
|
8
|
DC
INPUT CURRENT
|
|
I/P
: 12VDC
|
SPEC
:
|
NONE
|
|
O/P
: 300W
|
|
|
|
30.8A
|
|
|
9
|
EFFICIENCY
|
|
I/P
: 12VDC
|
SPEC
:
|
NONE
|
|
O/P
: 300W
|
|
|
|
83.4%
|
|
|
10
|
OVER
LOAD PROTECTION
|
|
I/P
: 12VDC
|
SPEC
:
|
NONE
|
|
O/P
: TESTING
|
|
|
324W
|
|
|
11
|
OVER
TEMPERATURE PROTECTION
|
|
I/P
: 12VDC
|
SPEC
:
|
55±5șC
|
|
O/P
: 300W
|
|
(THERMAL)
|
|
56.6șC
|
|
|
12
|
BURNIN
TEST
|
I/P:
12VDC O/P:270W TA:
25șC BURN-IN dur.:2 hrs
|
NO
BREAK
|
|
|
13
|
TEMPERATURE
RISE
T
rise OF PARTS
|
|
I/P
: 12VDC O/P : 270W AFTER : 2
hrs BURN-IN TA :
25șC
|
|
POSITION
|
P/N
|
TEMP
|
T
rise
|
|
C22
|
O/P
CAPACITOR
|
57.8șC
|
32.8șC
|
|
C11
|
I/P
CAPACITOR
|
52.0șC
|
27.0șC
|
|
Q15
|
O/P
TRANSISTER
|
42.7șC
|
17.7șC
|
|
Q4
|
I/P
TRANSISTER
|
63.8șC
|
38.8șC
|
|
T1
|
TRANSFORMER
|
79.0șC
|
54.0șC
|
|
D10
|
BRIDGE
|
94.2șC
|
69.2șC
|
|
|
THERMAL
|
50.6șC
|
25.6șC
|
|
|
|
14
|
LIFE
CYCLE
|
SUPPOSE
C11 IS THE MOST CRITICAL COMPONENT
I/P : 12VDC O/P : 270W Ta
: 25șC Tc11 :
52.0șC LIFE TIME
: hrs
|
|